    Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
    Position首頁 > Home > Industrial Safety Products > Safety interlock switch > foot switch
    FT foot switch

    image.png379.png

    ? Die-casting foot switch

    ? LHS series foot switches can prevent accidental misoperation

    ? Die-cast covers can protect the top and sides

    ? Contact: Multi-contact can be selected



    395181ccb7a771e30162f6415dc922a.png

    Product details

    product line

    1c42de46600a36c75caa6412a2cc3b7.pngd42687b.png18511e738bb57f7c6037896bd4a517a.pngcc1d5ea705e88d955d0891f0494f585.png

    product model

    FT-D02

    FT-D03

    FT-Q01

    product category

    electrically driven

    electrically driven

    Pneumatic drive

    Anti-treading function

    YES

    YES

    YES

    contact

    1NC+1NO

    2NC+2NO

    Two-position tee

    Two-position four-way

    material

    5mmHeavy steel

    5mmHeavy steel

    die-cast

    measure

    230×153×130(mm)

    270×165×140(mm)

    230×153×130(mm)

    Pedaling function

    Single tread plate

    Single tread plate

    Single tread plate

    mechanical life

    >1,000,000次

    >1,000,000次

    >1,000,000次

    rated voltage

    AC250V/125V

    AC250/125V

    NA

    contact rating

    15A

    15A

    NA

    resistance to impact

    30g/11ms

    30g/11ms

    10g/11ms

    environmental conditions

    ambient temperature: -25 ℃ … +60 ℃ 

    Storage and transportation temperature: -25 ℃ ... +85 ℃

    Protection type

    IP65

    Overvoltage category

    III 

    Overvoltage category

    3

    Rated impact resistance voltage Uimp

    6kV 

    Rated isolation voltage Ui

    500V 

    Thermal test current Ithe

    10A


    395181ccb7a771e30162f6415dc922a.png

    security level/phase

    Standard: EN ISO 13849-1

    B10D normally closed contact: 100,000

    Service life: 20 years

    圖片2.png

    1 pedal

    1 normally open+1 normally closed/2 normally closed +2 normally open


    395181ccb7a771e30162f6415dc922a.png

    functional check

    The safety function of the safety switch must be tested. Check and meet the following conditions in advance

    1. Check whether the incoming cable and connection are complete.

    2. Check whether the switch housing is damaged.

    3. Check the switch function by operating the safety foot switch.

    Note:

    Forced disconnection of normally closed contacts

    L left pedal

    R right pedal

    2dcf88ba997023b440e5de9ba51777a.pngd811d99f0c67c69f49aa602918a69b0.png


    395181ccb7a771e30162f6415dc922a.png

    Wiring instructions

    Palm line:------------- NO(normally open) 

    line:------------- NC(normal close)    

    black thread:------------- COM(the public side) 

    Yellow-green bicolor line:------------- PE(ground wire)

    腳踏開關接線說明.png

    Release status: black line (COM) and blue line (NC)

    On, black (COM) and brown line

    (NO) disconnect.

    Stepped state: black line (COM) and blue line (NC)

    Off, black (COM) and brown

    Line (NC) is on.


    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh